产品描述
SWITCHED ATS/STS 16a
Brief Introduction
KEJIA NKP-DY-TSU series ATS/STS(Automatic Transfer Switch) rack mount PDUs offer a redundant power option for single-corded network devices. Dual input cords support separate connection to primary and secondary power sources. The ATS/STS will normally supplies continuous power to all outlets as derived from the primary mains. If the primary power source becomes unstable or failed, the ATS/STS will switch over automatically to the secondary power source until the primary input is restored and stable. Super-fast switchover between primary and secondary power sources occurs within milliseconds, ensuring an uninterrupted power supply in data centers, telecom rooms, hospitals, banks, etc.
Main Features
- Dual input powers provide automatically redundant power protection.
- Built-in web server to manage PDU by network in real time
- Provide voltage, frequency, power factor, active power, apparent power and kWh information
- True RMS Current Meter
- Local LED Displays Amps, IP Address
- 10 Base-T Ethernet Port
- IPv4 Support
- SNMP Support (v1)
- SSL Web Browser (Https) for Set Up and Operation
- Alarm Notification via Email and SNMP
- User Defined Alarm Thresholds
- Circuit Breaker Protection
- Connect up to 1 Temperature and Humidity Probe
Typical Application
Auto-Transfer Switch/Switched ATS/STS PDU is ideal for providing switched outlet functionality and redundant A/B power to single-corded network equipment
Product Parameter
Model No. | NKP-DY-TSU-16a(ZN16-L52-2L2H) |
---|---|
Model No. | NKP-DY-TSU-16a(ZN16-L52-2L2H) |
PDU Type | ATS/STS/switched |
GENERAL | |
Nominal Input Voltage | 220V-230V, single phase |
Maximum Input Current | 16A |
Inlet | (2) IEC C20, enclosed C19 to C20 power cord, 3m |
Outlet | (10) IEC C13, 250V/10A |
Frequency | 50/60Hz |
Output Maximum Current | 10A |
CIRCUIT PROTECTION | |
LED Indicator | SSL: (1) YELLOW LED; |
DHCP: (1) GREEN LED | |
INPUT STATUS:(2) RED LED | |
OUTPUT STATUS:(2) GREEN LED | |
FUNCTION | |
Auto-transferred function: (A: primary power source, B: secondary power source ) - both primary (A) and secondary (B) power sources are available. A is set as default mains. If A becomes unstable or failed, it will switch over automatically to B until A is restored and stable | |
Transfer Time | 8-16ms |
Network Protocol | Http(s), SNMP, DHCP,UDP |
Network Interface | RJ45 connector to Ethernet |
Energy Metering | Voltage(V),Current(A), Active Power(kW), Apparent Power(kVA), Energy(kWh), Frequency |
Voltage(V) | ± 2% @ 90V~260V |
Current(A) | ±2%/±-0.1AMP @ 0A ~ 20 A |
Active Power(W) | ± 2% @ 50W~5000W |
Apparent Power(VA) | ± 2% @ 50VA~5000VA |
Frequency | ± 2% @ 45~65Hz |
Power Factor | ± 0.02 @ 0.5~1.0 |
Energy(kWh) | Range: 0.001kWh ~ 99999.999kWh; |
Precision: ±2% @ 50W~5000W, kh=1.0 | |
Onboard Display | 3 Digital Seven-segments for True RMS Meter |
Environmental Metering | Temperature, Humidity (±2%/±0.1) |
Environmental Interface | (1) RJ11 for ENV probe connection(extensional) |
OPERATIONAL ENVIRONMENT | |
Operating Temperature Range | 0℃-40℃(0℉-104℉) |
Storage Temperature Range | 0℃-40℃(0℉-104℉) |
Relative Humidity(RH) | 0%-90% |
Operating Elevation | <3000m(9873ft) |
PHYSICAL | |
Housing Material | Aluminum alloy, black |
Unit Dimension(LWD/mm) | 432*44.5*260 |
Unit Weight(NW/kg) | 4.8 |
PDU Mounting Form | 1U Horizontal |
ACCESSORIES | |
Package Includes | Rack mounting brackets, product manual |
TEST STANDARDS | |
Product Test | CE-LVD, CE-EMC, RoHS-2011/65/EU compliant |
WARRANTY | |
Product Warranty Period | 2-year warranty |