Location:Home > Products > NKB-40
■ Features:
● Include 4 independent input units,equal to 4 ways of transmitter input,with isolation between every unit
● The combination of AC voltage,AC,DC voltage,DC,temperature and other input units are selective when needed
● With RS485 output interface,be applicable for a variety of communication codes
● Low temperature floats characteristic, high-impact voltage and insulation characteristic
● Stable performance,reliable quality
● The power supply, signal input and output terminals can offer the function of lightning protection and a selective purchasing
● Applicable for the automatic control of the engineerings like circuit system,intelligent buildings
■ Code Illustration:
Input Type:
0: AC
1: AC voltage
4: Temperature
6: DC
7: DC voltage
NKB-40-□□□□---the Fourth Road type input type
the Third Road input type
the Second Road input type
the First Road input type
40-type combined intelligent transmitter
■ Technical Specification:
|
Input Scope: 0-60V | |
|
AC |
0~1A 50Hz±3Hz 60Hz±3Hz |
|
0~5A 50Hz±3Hz 60Hz±3Hz | |
|
AC Voltage |
0~150V 50Hz±3Hz 60Hz±3Hz |
|
0~300V 50Hz±3Hz 60Hz±3Hz | |
|
0~500V 50Hz±3Hz 60Hz±3Hz | |
|
DC |
0~75mV |
|
0~200mV | |
|
DC Voltage
|
0~60V |
|
0~150V | |
|
0~300V | |
|
Temperature |
0~100℃ |
|
-30~100℃ | |
|
0~150℃ | |
|
0~600℃ | |
-Power supply changes: ≤0.05% rated output
-Energy consuming: ≤ 2.5VA(single item two-wire)
≤ 6.5VA(three-phase three-wire)
-Interference effects: ≤ 0.1% rated output,between the components
-Effect of magnetic field strength: 400 ATM ≤ 0.2% rated output
-Insulation strength: IEC414,IEC688:1992,ANSI C37.90a
between the input/output/power supply and outer shell
AC4KV, 50/60Hz, a minute
-Imax: 3kA(8/20μs)
-Vp: <1500V
-Operaing temperature: -10 ℃~ 60 ℃
-Working relative humidity: 20-95%RH and with no condensation
-Voltage-shock tests: IEC255-4,ANSI C37.90a
6KV, 1.2×50μ sec CM&DM
-Safty norm: IEC414,BS5458
-Output interface: RS485
-Installation: Track installation(EN50022)
-Communication code: Modbus, IEC103
-Baud rate: 1200bps-38400bps
-Accuracy: ≤±0.2% rated output
-Waveform influence: ≤0.2% rated output,30% waveform distortion
-Over-voltage input capability: Voltage:1.5×rated continuous input,2×rated input within 10s,4×rated input within 2s Current:3×rated continuous input 10×rated input within 10s 50×rated input within 1s
-Power supply: AC115/230V±15%,50/60Hz AC380/415V±15%,50/60Hz
Special election:DC24V, 48V, 110V, 220V±10%